Co de 39
Nugget
Configuration Command Reference
9-55
9
End of Message (EOM)
Purpose: Attaches an EOM to the end of a data block to indicate the end of data transmission to
and from a terminal. When EOM is disabled, the terminal communicates in Character
mode. When EOM is enabled, the terminal communicates in Frame mode.
You must configure a value for EOM before you can set these other serial
communications commands:
Configuration Commands Via Serial Port
Handshake
LRC
Start of Message (SOM)
EOM cannot equal the same value that is set for SOM. You cannot set EOM to any of
these values:
AFF (ACK) REQ (ENQ)
DLE SEL
NEG (NAK) XOFF
Poll XON
RES (EOT)
Syntax: YZ
n
.
data
where
n
is:
1 COM1 port
3 COM3 port
4 COM4 port
Acceptable values for
data
are one or two ASCII characters.
Default: \x03 (hexadecimal value for ETX)
Scan: To disable EOM, scan one of these bar codes:
Disable EOM for COM1 Disable EOM for COM4
*$+YZ1.* *$+YZ4.*
*$+YZ1.* *$+YZ4.*