TRAKKER Antares 2420 and 2425 Hand-Held Terminal User’s Manual
Co de 39
Nugget
9-68
LRC (Longitudinal Redundancy Check)
Purpose: The Longitudinal Redundancy Check (LRC) character is an error-checking character that
you can append to transmitted and received blocks of data.
Note: Before you can enable LRC, you must enable the EOM command.
Syntax: YFn.data
where n is:
1 COM1 port
3 COM3 port
4 COM4 port
Acceptable values for data are:
0 LRC disabled
1 LRC enabled
Default: Disabled
Scan: One of these bar codes:
Disable LRC for COM1 Enable LRC for COM1
*$+YF1.0* *$+YF1.1*
*$+YF1.0* *$+YF1.1*
Disable LRC for COM3 Enable LRC for COM3
*$+YF3.0* *$+YF3.1*
*$+YF3.0* *$+YF3.1*
Disable LRC for COM4 Enable LRC for COM4
*$+YF4.0* *$+YF4.1*
*$+YF4.0* *$+YF4.1*
Notes: For COM1 only. To provide compatibility with earlier TRAKKER Antares firmware
versions, you can also use this syntax:
IFdata
where data is a value of 0 or 1.