Getting Started
1-19
1
Configuring the Serial Port Parameters
You use the terminal’s serial port and a communications dock, optical link adapter, or
serial interface module to transfer data in a wired network between the terminal and a
host computer, printer, or other RS-232 serial device. If your T2420 has a modem, you
can send files and data over a phone connection.
Host computer
Terminal in TD2400
communications dock
To power
supply
242XU.160
You need to set these serial port parameters to have the terminal communicate with a host
computer or serial device in a wired network:
Serial Port Parameter Default Value
Baud rate 19200
Data bits 7
EOM (End of Message) \x03 (hexadecimal value for ETX)
Flow control None
Handshake Disabled
LRC Disabled
Modem dial sequence (COM3 only) No dial sequence
Modem initialization sequence (COM3 only) Auto rate
Parity Even
Poll (Polling) Disabled
Serial port protocol Configurable
SOM (Start of Message) \x02 (hexadecimal value for STX)
Stop bits 1
Timeout delay 10 seconds