Chapter 5: Changing the System Setup
MP65492–1 105 Linx 4900 Operating Manual
3. At the ALARM menu:
• The Mode option allows the alarm output to be changed to
activate the external alarm, as follows:
Note that once system events are cleared, the alarm output is
automatically deactivated.
• The following options can be set to Yes (On) or No (Off), as
follows:
4. Press the [enter] key to save each setting.
5. Press the [esc] key to exit.
Select this setting... To...
Continuous Sound the external alarm continuously
when a System Warning event occurs.
Pulsed Pulse the external alarm on/off twice, in
time with the internal alarm when a
System Warning event occurs.
Sound the external alarm continuously
when a System Failure or Print Failure
event occurs.
Set this option to Yes... To...
Failure Sound the external alarm
continuously when a Print Failure
event occurs.
Warning Pulse the external alarm on/off
twice, or, sound alarm continuously
when a system failure event
occurs—depending on the Mode
option setting above.
Print Disabled Sound the external alarm
continuously when the printer
cannot print for any reason, e.g jet
stopped, printhead cover removed.
As soon as printing is resumed, or
when the printer is printing, the
alarm is switched off.
Ink and Solvent Sound the external alarm
continuously, or, pulse the external
alarm on/off twice when a “3.03 Ink
Low” or “3.04 Solvent Low” event
message occurs—depending on the
Mode option setting above.