92
Tamper alarm
o Arm (default): In case of a tampering alarm, the sirens sound an alarm only
in arm mode. They remain silent in all other modes (Disarm, Home 1-3).
o Always: In case of a tampering alarm, the sirens always sound an alarm –
irrespective of the alarm mode of the alarm panel.
Time settings
Schedule for sensor verification
At regular intervals, the alarm panel checks if the added sensors are still connected
to the alarm panel. We highly advise you keep this option enabled. If a sensor does
not send a status signal to the alarm panel during this interval, the alarm panel lists
this as an error, the sensor is marked as “out of order”, and the alarm panel emits
a notification sound every 30 seconds. Depending on your setup, you are notified
via contact ID, e-mail, SMS, or Push-Notification.
Please note:
o The alarm panel receives status information from every sensors on a
regular basis (every 30-50 minutes).
o After a reboot of the alarm panel, there are no status information available.
Hence, the sensors are displayed without their current status. If a sensor is
open and its status changes from “N/A” to “open”, an alarm is triggered, if
the sensor should trigger an alarm in the current mode of the alarm panel.
Entering delay (1 and 2)
If you enter your house while the alarm panel is armed, you may need a certain
time to disarm the alarm panel by e.g. entering the code in the keypad. This setting
allows you to specify the required delay time until an alarm should be triggered.
This only applies to sensors with the ‘arm response’ “Entry delay 1 or 2” (see
chapter “Edit sensors”). Sensors with the attribute “Burglar alarm instant” will
always trigger an alarm immediately.
Exit delay
If you arm the alarm panel, you may need a certain time to leave the house. This
option allows you to set this delay time. After the delay has expired, the alarm panel
is armed.
Please note:
o Additionally, you need to enable the option “mind the exit delay” in the
sensor edit menu of each sensor that should not trigger an alarm during this
delay time. This option can be set individually for every alarm mode.
o The exit delay is active irrespective of the way you arm your alarm panel
(e.g. Keypad, Remote control, Tag Reader V2, Web browser, or App).
Entry delay time 1 & 2 (home modes)
If one of the home modes is active and a sensor with the setting delay upon entry
(1 or 2) for home 1 / 2 / 3 response is triggered, the delay time is started and an
alarm will only sound if the alarm panel is not disarmed in the set time.
Exit delay time (home modes)
If the Home mode is activated e.g. via the keypad, you will usually need time to
leave the house or premises. You can set the delay before the alarm is triggered
here. Please observe the note under “Delay upon exit”.