Function SPM Bit Description
clr marker 2 X65 = 0 Clear marker 2
clr marker 3 X66 = 0 Clear marker 3
select gross X72 = 0 Save the gross weight in address D11
Actions can be selected (bits set) for all digital inputs (see table).
Define the action for the rising edge of Input 1 (in this case: When the input signal
changes from 0 to 1, a tare command is generated).
Accordingly, an action for the falling edge can be determined.
7.18.8.2 Determining a condition
The selected action of each digital input can be combined with a condition that must be
met for signal change from 0 to 1 (on) or for signal change from 1 to 0 (off). The condition
is selected from the list in Chapter 7.18.7.3.
No condition is defined when selecting [no condition]. The action is executed directly.
1. Select the appropriate line using the cursor (here: Input 1 on) and confirm.
A selection window opens.
2. Select and confirm the appropriate line.
3. If applicable, select additional actions (setting bits) and confirm.
X3 Process Indicator PR 5410 7 Getting started
EN-252 Minebea Intec