4.6.5.4 External voltage supply specifications
If more than four Connexx modules are to be connected, an external power supply must
be used for the voltage supply.
Ambient conditions
Ambient temperature for operation -25…+70 °C
Interference resistance EN 61000-6-2:2005
Entry data
Nominal input voltage range U
AC
= 100…240 V
Input voltage range AC U
AC
= 85…264 V
Frequency range AC 45…65 Hz
Output data
Nominal output voltage U
DC
= 24 V ±1 %
Output current 1.0 A
Connection data output
Connection type 1× terminal, 2-pin
Phoenix Contact MVSTBW 2.5/2-ST-5.08
4 Device installation X3 Process Indicator PR 5410
Minebea Intec EN-77