- 10 - NOTICE (PLACING EQUIPMENT)
GGS-000544-01E iPASOLINK EX Advanced: SAFETY INFORMATION
NOTICE (PLACING EQUIPMENT)
1. iPASOLINK EX/A generates non-ionizing radiation, and is designated for
the outdoor use. Installing the equipment indoors may cause bodily harm
nor inflict damage to objects, which needs to take the adequate measures, if
occurs.
2. iPASOLINK EX/A should be installed as follows:
Verify that the equipment is installed in the appropriate site. Do not
install it on an unstable spot. Improper installation raises the
temperature inside the equipment, which may damage the
equipment.
Accessing to the equipment should be limited only by the SERVICE
PERSONNEL or by USERS WHO ARE WELL TRAINED WITH
ENOUGH SKILLS AND KNOWLEDGES REGARDING THESE
RESTRICTIONS, PRECAUTIONS AND INSTALLATION SITES.
Accessing to the equipment must be protected using a tool, locks,
keys, and/or other means of security, which should be managed by
the authority who is responsible for the installed site.
The other end of the grounding cable connected to the ground
terminal should be connected to the station earth point. For details,
refer to the Installation Manual.
3.
Precautions for Cables:
(a) POWER SUPPLY CABLES
Use two-core double insulated cable of 5.86 to 10.00 mm in diameter.
(b) D
ATA TRANSMISSION CABLES
Use shielded cables for the data transmission cables.
(c) G
ROUNDING
Ground Terminal should be connected to the station earth point. For
details, refer to the Grounding the Frame section in the Installation
manual.
4.
Transmission quality degradation may temporarily occur due to the
electromagnetic disturbances, such as lightning or ESD.