EasyManuals Logo

NSK Megatorque PS Series User Manual

NSK Megatorque PS Series
370 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #167 background imageLoading...
Page #167 background image
— 8-7 —
The example shown below describes how to change the function of input port PI14 from the
input PRG7 (Internal program channel selection) to the input HLD (Hold).
1) Input the command MO (Motor off) to deactivate the Motor servo.
:
MO
:_
O M
ENT
2) Specify the input port number by the command PI to display the setting of the
parameter FN. (Port parameter) (The shipping set of the input port is PRG7.)
:
P
I14
FNPRG7;
AB0;
NW0.2
I P
ENT
4
1
SP SP
Every input of the SP key reads out the parameter AB and the parameter NW.
3) Change the function to the input HLD.
AB0;
NW0.2
?
FNHLD
?_
N F L H
ENT
D
Set the parameter AB and the NW in the same way.
4) Input “?” when the prompt “?” is on the last line to confirm the settings.
?
?
FNHLD;
AB0;
NW0.2
?
ENT
SP SP
Every input of the SP key reads out the parameter FN setting, the parameter AB,
and the parameter NW.
5) Input the ENT
key to complete editing, while the prompt “?” is on the screen.
NW0.2
?
:_
ENT
6) Activate the Motor servo by the command SV (Servo on).
:
S
V
:_
V S
ENT

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NSK Megatorque PS Series and is the answer not in the manual?

NSK Megatorque PS Series Specifications

General IconGeneral
BrandNSK
ModelMegatorque PS Series
CategoryEngine
LanguageEnglish

Related product manuals