— 9-18 —
ED: (Factory use only)
This monitor is for factory use only.
EDF: (Factory use only)
This monitor is for factory use only.
EDV: (Factory use only)
This monitor is for factory use only.
FACLR: Function ACLR
This is to monitor the condition of the input ACLR (Alarm clear).
Refer to “7.3.1.5.Monitor for Individual Function” for details.
The monitored state is after application of the parameters AB (Polarity) and NW (Anti-chattering
timer) in the command PI (Edit input port).
Category Monitor
Format
FACLR
0
: Off
Data range
1
: On
FBUSY: Function BUSY
This is to monitor the state of output BUSY(In-operation).
Refer to “7.3.1.5. Monitor for Individual Function” for details.
For the monitored state, the parameters ST (Stability timer) and GC (Output logic) in the
command PO (Edit output port) are not applied.
Category Monitor
Format
FBUSY
0
: Idle
Data range
1
: In operation
Ì
FD: Feedback Direction Mode
This parameter sets the phase relation between the phase A and phase B of position feedback
signal.
Category Parameter
Format
FD data
0
: Phase A is leading in the CW direction
Data range
1
: Phase B is leading in the CW direction.
Shipping set 0