— 9-26 —
P FS: Low-pass Filter, Secondary
Sets the low-pass filter to the torque command.
Refer to “8.5.2. Digital Filter” for details.
Category Parameter
Format
FS data
Data range 1 0
: Secondary low-pass filter is OFF.
Data range 2 10 to 1000 [Hz]
Shipping set 0
This parameter will be automatically set by an execution of the command AT (Automatic
tuning).
FSTP: Function STP
This is to monitor the state of the input STP (Stop).
Refer to “7.3.1.5. Monitor for Individual Function” for details.
The monitored state is after application of the parameters AB (Polarity) and NW (Anti-chattering
timer) in the command PI (Edit input port).
Category Monitor
Format
FSTP
0
: Operation available.
Data range
1
: Start deceleration, and operation prohibited.
FSVON: Function SVON
This is to monitor the state of the input SVON (Servo on).
Refer to “7.3.1.5. Monitor for Individual Function” for details.
The monitored state is after application of the parameters AB (Polarity) and NW (Anti-chattering
timer) in the command PI (Edit input port).
Category Monitor
Format
FSVON
0
: Servo OFF.
Data range
1
: Servo ON.