EasyManuals Logo

NSK Megatorque PS Series User Manual

NSK Megatorque PS Series
370 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #282 background imageLoading...
Page #282 background image
— 9-58 —
Ì
P PP: Parameter Prompt
There are two prompts for programming to distinguish which parameter is effective: the local
parameter that is changed especially for a program channel or the global parameter that is set by
the normal prompt.
“:” : Global parameter is effective.
“: >” : Local parameter is effective.
When the parameter is set via RS-232C communication, both parameters,
global and local, are set to the channel, even the prompt is “:>”.
Setting the parameter PP0 will make possible not change the prompt.
Refer to “6.3.2.2. Program Positioning Operation via RS-RS-232C Communication”
for details.
Category Parameter
Format
PP data
0
: Does not change the prompt. (Always “:”)
Data range
1
: Indicates the effective parameter. (“:” of “: >)
Shipping set 1
Ì
P PS: Position Scale Select
This parameter specifies the position scale system.
Category Parameter
Format
PS data
Data range 1
: One revolution position scale
Shipping set 1
PWU: (Factory use only)
This monitor is for factory use only.
PWV: (Factory use only)
This monitor is for factory use only.
PWW : (Factory use only)
This parameter is for factory use only.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NSK Megatorque PS Series and is the answer not in the manual?

NSK Megatorque PS Series Specifications

General IconGeneral
BrandNSK
ModelMegatorque PS Series
CategoryEngine
LanguageEnglish

Related product manuals