— 9-71 —
P TTO : Tell Torque Command, Over
This parameter sets the threshold to activate the putout TTO (Torque command over).
Refer to “8.3.2.3. Torque Command: Output TTU (Torque command, under) and
Output TTO (Torque command, over) for details.
The output TTO activates when the torque command is greater or equal to the
threshold specified by the parameter TTO.
Category Parameter
Format
TTO data
Data range 0.00 to 100.00%
Shipping set 0.00
P TTU: Tell Torque Command, Under
The parameter sets the threshold to activates the TTU (Torque command, under)
Refer to “8.3.2.3. Torque Command: Output TTU (Torque command, under) and
Output TTO (Torque command, over) for details.
The output TTU activates when the torque command is less or equal to the threshold
set by the parameter TTU.
Category Parameter
Format
TTU data
Data range 0.00 to 100.00%
Shipping set 0.00
TV: Tell Velocity
Reads out the current velocity.
Refer to “7.3. RS-232C Monitor” for details.
Command Monitor
Format
TV
Data range 0.000 to ± 10.000 [s
-1
]
(The data range is an approximate value.)
TVC: Tell Velocity Command
This monitor reads out the transient velocity command in the internal control block.
Refer to “7.3. RS-232C Monitor” and “8.5.1. Servo Block Diagram” for details.
Category Monitor
Format
TVC
Data range 0.000 to ±10.000 [s
-1
]