EasyManuals Logo

Promise Technology VTRAK E610f User Manual

Promise Technology VTRAK E610f
434 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #314 background imageLoading...
Page #314 background image
VTrak E-Class Product Manual
296
RAID 1
A RAID 1 Source logical drive can migrate to the following Target logical drives:
RAID 1E
A RAID 1E Source logical drive can migrate to the following Target logical drives:
RAID 60 8 physical drives minimum, 32 per axle maximum.
If existing physical drives have no unused space, add 1 or
more physical drives.
Target Requirements
RAID 0 None.
RAID 1E 3 or more physical drives.
Add 1 or more physical drives.
RAID 5 3 physical drives minimum, 16 maximum.
RAID 1 must have less than 16 physical drives.
Add 1 or more physical drives.
RAID 10 4 physical drives minimum.
Even number of physical drives.
Add 2 or more physical drives.
RAID 50 6 physical drives minimum, 32 per axle maximum.
Add 4 or more physical drives.
Target Requirements
RAID 0 None.
RAID 1E Add physical drives.
RAID 5 3 physical drives minimum, 16 maximum.
RAID 1E must have less than 16 physical drives.
If existing physical drives have no unused space, add 1 or
more physical drives.
Target Requirements

Table of Contents

Other manuals for Promise Technology VTRAK E610f

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Promise Technology VTRAK E610f and is the answer not in the manual?

Promise Technology VTRAK E610f Specifications

General IconGeneral
BrandPromise Technology
ModelVTRAK E610f
CategoryStorage
LanguageEnglish

Related product manuals