EasyManuals Logo

Promise Technology VTRAK E610f User Manual

Promise Technology VTRAK E610f
434 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #316 background imageLoading...
Page #316 background image
VTrak E-Class Product Manual
298
RAID 10
A RAID 10 Source logical drive can migrate to the following Target logical drives:
When you migrate RAID 10 logical drive, it becomes RAID 1E by default.
If you want a RAID 10 logical drive, there must be an even number of physical
drives and you must specify RAID 10 for the target logical drive.
RAID 60 8 physical drives minimum, 32 per axle maximum.
If existing physical drives have no unused space, add 1 or
more physical drives.
Target Requirements
RAID 0 None.
RAID 1E None.
RAID 5 3 physical drives minimum, 16 maximum.
RAID 10 must have less than 16 physical drives.
RAID 6 4 physical drives minimum, 16 maximum.
RAID 10 must have less than 16 physical drives.
If existing physical drives have no unused space, add 1 or
more physical drives.
RAID 10 Add physical drives.
Even number of physical drives.
RAID 50 6 physical drives minimum, 32 per axle maximum.
RAID 60 8 physical drives minimum, 32 per axle maximum.
If existing physical drives have no unused space, add 1 or
more physical drives.

Table of Contents

Other manuals for Promise Technology VTRAK E610f

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Promise Technology VTRAK E610f and is the answer not in the manual?

Promise Technology VTRAK E610f Specifications

General IconGeneral
BrandPromise Technology
ModelVTRAK E610f
CategoryStorage
LanguageEnglish

Related product manuals