RL78/G15 CHAPTER 6 TIMER ARRAY UNIT
R01UH0959EJ0110 Rev.1.10 Page 176 of 765
Mar 7, 2023
(ii) When timer data register mn (TDRmn) is used as capture register
The count value of timer count register mn (TCRmn) is captured to the TDRmn register when the capture trigger is input.
A valid edge of the TImn pin can be selected as the capture trigger. This selection is made by timer mode register mn
(TMRmn).