RL78/G15 CHAPTER 13 SERIAL INTERFACE IICA
R01UH0959EJ0110 Rev.1.10 Page 571 of 765
Mar 7, 2023
(d) Start ~ Address ~ Data ~ Start ~ Address ~ Data ~ Stop
(i) When WTIM0 = 0 (an address mismatch after restart (other than extension code))
1
3
4
2
ST
AD6-AD0
R/W
D7-D0
ST
AD6-AD0
D7-D0
SP
ACK
R/W
ACK
ACK
ACK
1: IICS0 = 0001×110B
2: IICS0 = 0001×000B
3: IICS0 = 00000×10B
4: IICS0 = 00000001B
Remark : Always generated
: Generated only when SPIE0 = 1
×: Don’t care
(ii) When WTIM0 = 1 (an address mismatch after restart (other than extension code))
1
3
4
2
ST
AD6-AD0
R/W
D7-D0
ST
AD6-AD0
D7-D0
SP
ACK
R/W
ACK
ACK
ACK
1: IICS0 = 0001×110B
2: IICS0 = 0001××00B
3: IICS0 = 00000×10B
4: IICS0 = 00000001B
Remark : Always generated
: Generated only when SPIE0 = 1
×: Don’t care