15.4 Communication Cable for Control Cabinet
2 m long cable FRKS0006/002,0 or 3 m long cable FRKS0004/003,0 can be used
for the connection of the operating panel.
15.5 Extension Card Module
15.5.1 Extension Card Module Mounting
Please make sure the power supply has been switched off before mounting the
extension card module onto the frequency converter.
Fig. 15-6: Extension card module mounting
1. Remove operating panel â‘£ from Control & Terminal module â‘ .
2. Mount extension card module with extension cards â‘¡ into Control & Termi-
nal module â‘ .
3. Tighten two screws â‘¢ to fix carrier for option modules â‘¡ in Control & Ter-
minal module â‘ .
4. Push operating panel â‘£ into carrier for option modules â‘¡.
⑤
: Control & Terminal module connector
â‘¥: Connector for operating panel
Bosch Rexroth AG
Accessories
EFC x610 Series
290/389