19.6.3 Commission
Always test the operation and reaction of the STO function before commission-
ing.
Dangerous movements! Danger to life, risk of in-
jury, serious injury or property damage!
WARNING
Do not commission the installation without having it checked by a qualified per-
son!
Before an installation with integrated safety technology is commissioned for the
first time, the installation must be checked and approved in documented form
by a qualified person.
Check the danger zone!
Before commissioning, make sure that nobody is staying in the danger zone.
Check the danger zone and secure it against access by persons (e.g., put up
warning signs, install barriers or the like). Observe the applicable laws and lo-
cal regulations.
Bosch Rexroth AG
Appendix
EFC x610 Series
384/389
DOK-RCON03-EFC-X610***-IT05-EN-P