12.4 Basic Frequency Setting Sources
12.4.1 Function Description
Four means of frequency setting sources are available with priority (0, 1, 2, 3) as
shown in the figure below.
Only frequency setting source of the fourth priority '3: Basic frequency setting
sources' is introduced in this chapter. Other frequency setting sources of '0: PID
control', '1: Simple PLC' and '2: Jog function' will be introduced later in separate
chapters.
f
SRC1
First frequency setting source
f
SRC2
Second frequency setting source
0 First priority (PID control)
1 Second priority (Simple PLC)
2 Third priority (Jog function)
3 Fourth priority (Basic frequency setting
sources)
f
Set
Setting frequency
Fig. 12-10: Frequency setting sources