12.4.3 Acceleration and Deceleration Configuration
Acceleration and deceleration time configuration
Acceleration / deceleration time setting is the time for frequency increase from
0.00 Hz to [E0.08] 'Maximum output frequency' / the time for frequency de-
crease from [E0.08] to 0.00 Hz respectively.
Fig. 12-18: Acceleration and deceleration time
8 groups of acceleration / deceleration time are available, which can be selected
by setting digital inputs.
Code
Name Setting range Default Min. Attri.
E0.26 Acceleration time 0.1...6,000.0 s DOM 0.1 Run
E0.27 Deceleration time 0.1...6,000.0 s DOM 0.1 Run
E3.10 Acceleration time 2 0.1...6,000.0 s 10.0 0.1 Run
E3.11 Deceleration time 2 0.1...6,000.0 s 10.0 0.1 Run
E3.12 Acceleration time 3 0.1...6,000.0 s 10.0 0.1 Run
E3.13 Deceleration time 3 0.1...6,000.0 s 10.0 0.1 Run
E3.14 Acceleration time 4 0.1...6,000.0 s 10.0 0.1 Run
E3.15 Deceleration time 4 0.1...6,000.0 s 10.0 0.1 Run
E3.16 Acceleration time 5 0.1...6,000.0 s 10.0 0.1 Run
E3.17 Deceleration time 5 0.1...6,000.0 s 10.0 0.1 Run
E3.18 Acceleration time 6 0.1...6,000.0 s 10.0 0.1 Run
E3.19 Deceleration time 6 0.1...6,000.0 s 10.0 0.1 Run
E3.20 Acceleration time 7 0.1...6,000.0 s 10.0 0.1 Run
Bosch Rexroth AG
Functions and Parameters
EFC x610 Series
142/389
DOK-RCON03-EFC-X610***-IT05-EN-P