Standard Relevant to Safety Function
EFC 5610 frequency converter* is comply with the following relevant safety
standards:
Standard Description
IEC 61508 2010-4
Functional safety of electrical/electronic/programmable electronic
safety-related systems
ISO 13849-1 2006
Safety of machinery-safety-related parts of control systems-Part 1:
General principles for design
ISO 13849-2 2008
Safety of machinery-safety-related parts of control systems-Part 2: Val-
idation
IEC 62061 2012-11
Safety of machinery-Functional safety of electrical, electronic and pro-
grammable electronic control systems
IEC 61800-5-2 2007
Adjustable speed power drive systems- Part 5-2: safety requirements-
Functional
IEC 60204-1 2009 Safety of machinery- Electrical equipment of machines
Tab. 19-3: STO relevant safety standards
● *: Currently only 30...90 kW modules support the STO function.
● The safety function corresponds to stop category 0 according to
IEC 60204-1.
Bosch Rexroth AG
Appendix
EFC x610 Series
378/389