4.4 Transport of the Components
Description Symbol Unit Value
Temperature range
T
a_tran
-25…70
Relative humidity % 5…95
Absolute humidity
g/m
3
1…60
Climate category (IEC 721) 2K3
Moisture condensation not allowed
Icing not allowed
Tab. 4-1: Transport conditions
4.5 Storage of the Components
CAUTION
Damage to the components caused by long storage periods!
A frequency converter contains electrolytic capacitors which may deteriorate
during storage.
When storing these components for a long period of time, remember to operate
them once a year:
Run Frequency Converter EFC x610 under power U
LN
for at least 1 hour.
For more information of electrolytic capacitors, please contact service.
Description
Symbol Unit Value
Temperature range
T
a_store
-20…60
Relative humidity % 5…95
Absolute humidity
g/m
3
1…29
Climate category (IEC 721) 1K3
Moisture condensation not allowed
Icing not allowed
Tab. 4-2: Storage conditions
EFC x610 Series Bosch Rexroth AG
Delivery and Storage
DOK-RCON03-EFC-X610***-IT05-EN-P
17/389

Table of Contents

Other manuals for REXROTH EFC 3610 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the REXROTH EFC 3610 Series and is the answer not in the manual?

REXROTH EFC 3610 Series Specifications

General IconGeneral
BrandREXROTH
ModelEFC 3610 Series
CategoryDC Drives
LanguageEnglish

Related product manuals