Limited* Parameters
Code Name Code Name
b0.00 Access authority setting E9.01 Automatic error reset interval
E0.45 Power loss restart mode E9.05 Last error type
E0.46 Power loss restart delay E9.06 Second last error type
E8.00 Communication protocol E9.07 Third last error type
E8.01 Communication error detection time E9.10 Output frequency at last error
E8.02 Communication error protection mode E9.11 Setting frequency at last error
E8.10 Modbus baud rate E9.12 Output current at last error
E8.11 Modbus data format E9.13 Output voltage at last error
E8.12 Modbus local address E9.14 DC bus voltage at last error
E9.00 Automatic error reset attempts E9.15 Power module temperature at last error
Tab. 8-11: Limited parameters
Make sure that the voltage on DC_IN terminal is within 20...28 V, oth-
erwise error code 'EPS-' will be displayed.
Bosch Rexroth AG
Frequency Converter Wiring
EFC x610 Series
62/389
DOK-RCON03-EFC-X610***-IT05-EN-P