4.Service Tables
67
memory to the format which was specified in the set-up protocol
(DIS/NSF) before transmission.
Do not change the factory settings.
Available unit of resolution in
which fax messages are received
For the best performance, do not change the factory settings.
The setting determined by these bits is informed to the transmitting terminal
in the pre-message protocol exchange (in the DIS/NSF frames).
Communication Switch 15 – Not used (do not change the settings)
Communication Switch 16 (SP No. 1-104-023)
Do not change the settings.
0: Not installed
1: Installed
Change this bit to 1 when installing the first optional G3 unit.
This switch enables the G3-2.
0: Off, no connection
1: Recognizes and enables G3-2.
This switch can be used only after G3-2 has been installed.
Do not change the settings.
Communication Switch 17 (SP No. 1-104-024)
0: Polling transmission to another maker's machine using the SEP
(Selective Polling) signal is disabled.
0: Confidential reception to another maker's machine using the SUB
(Sub-address) signal is disabled.
0: Disables features that require PWD (Password) signal reception.