4.Service Tables
94
Address
Function
Unit
Remarks
limit (high byte)
detection is disabled.
680535
International dial tone frequency upper
limit (low byte)
680536
International dial tone frequency lower
limit (high byte)
Hz (BCD)
If both addresses contain FF (H), tone
detection is disabled.
680537
International dial tone frequency lower
limit (low byte)
680538
International dial tone detection time
20 ms
If 680538 contains FF, the machine pauses
for the pause time (68053D / 68053E).
Belgium: See Note 2.
680539
International dial tone reset time (LOW)
68053A
International dial tone reset time (HIGH)
68053B
International dial tone continuous tone
time
68053C
International dial tone permissible drop
time
68053D
International dial wait interval (LOW)
-
68053E
International dial wait interval (HIGH)
68053F
Country dial tone upper frequency limit
(HIGH)
Hz (BCD)
If both addresses contain FF (H), tone
detection is disabled.
680540
Country dial tone upper frequency limit
(LOW)
680541
Country dial tone lower frequency limit
(HIGH)
If both addresses contain FF (H), tone
detection is disabled.
680542
Country dial tone lower frequency limit
(LOW)
680543
Country dial tone detection time
20 ms
If 680543 contains FF, the machine pauses
for the pause time (680548 / 680549).
680544
Country dial tone reset time (LOW)
680545
Country dial tone reset time (HIGH)
680546
Country dial tone continuous tone time
-
-
680547
Country dial tone permissible drop time
20 ms
-
680548
Country dial wait interval (LOW)
680549
Country dial wait interval (HIGH)
68054A
Time between opening or closing the
DO relay and opening the OHDI relay
1 ms
See Notes 3, 6 and 8. SP2-103-012
(parameter 11).
68054B
Break time for pulse dialing
1 ms
See Note 3.
SP2-103-013 (parameter 12).
68054C
Make time for pulse dialing
1 ms
See Note 3.
SP2-103-014 (parameter 13).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ricoh M0A0 and is the answer not in the manual?

Ricoh M0A0 Specifications

General IconGeneral
BrandRicoh
ModelM0A0
CategoryAll in One Printer
LanguageEnglish

Related product manuals