Software update
8-6 Chapter 8: Service & maintenance 98-137654-A
3. Open your Internet browser and enter the IP address of the ACU.
The IP address is http://192.168.0.1 (default). For further details
on network setup see Configuring the LAN network on page 6-25.
4. The web interface opens directly with the DASHBOARD page.
5. Click SERVICE from the left navigation pane. The Upload page is
displayed.
6. Click Browse... and locate the new software file.
7. Click Upload.
Note that the upload procedure takes a couple of minutes. When
done, the ACU automatically restarts with the new software
version.
The start-up procedure after a software upload takes longer than
the usual start-up time, as the software in the ADU must also be
updated. The ACU display shows: ADU SW UPLOAD.
8.2.2.2 If software upload fails - how to recover
To recover from a failed software upload, turn off the ACU and turn
it on again. Then repeat the upload procedure as described in
Software update on page 8-5.
8.2.3 Verifying the software update
8.2.3.1 Testing procedure
1. The software version can be viewed in the DASHBOARD window
of the web interface.
2. After completing the software update procedure, the ACU will
perform a POST (Power On Self Test).
3. When the POST has finished, the green Pass/Fail LED on the front
of the ACU must become steadily green. Verify that the Pass/Fail
LED is not red nor flashing orange once every 2 seconds. Wait
until the Pass/Fail LED is green.
4. Verify that the software update has been completed successfully.
You find the software version number in the DASHBOARD window
of the web interface.
Important
Do not browse away from the upload page. This
will terminate the upload process. Wait for the
browser to reload automatically.