Engineer programming via the browser
Installation & Configuration Manual
Text description of the door controller (max. 16 characters).
The type of expander detected (=door controller).
The serial number of the door controller.
The firmware version of the door controller.
The status of the door controller (online or offline).
The status of the door controller (OK, Fault).
Specifies if the door controller has a PSU.
Performable actions
Click on the refresh button to update the status of the system alerts.
To view more status information:
Click on a door controller’s identifying parameters (ID, description, type, serial
number) to display further status details.
The physical status (OK, Fault) and the programmed status (OK, Isolated,
Inhibited) of the keypad cable connection to the expander.
The physical and programmed status of the expander cabinet tamper.
The physical and programmed status of the door controller fuse.
Status of the user’s PIN. Multiple failed attempts result in an alert.
Performable actions
Click the button to restore all alerts on the panel.
Click this button to inhibit a fault condition. The inhibit operation will disable
that fault or zone for one arming period only.
Inhibit operation is not available in Security Grade EN 50131 Grade 3.
Click this button to isolate that zone. Isolating a zone will de-activate that zone
until such time as the zone is explicitly de-isolated again. It is recommended
that you exercise caution when isolating zones as those zones will not be
active every time the system is SET.