Engineer programming via the browser
Installation & Configuration Manual
User Profile
Type Default
Standard
Manager
Access Control
User can control RF output
User can perform a bell test to test the external bells,
strobe, internal bells and buzzer to ensure their correct
operation.
User can perform a walk test to allow for testing of the
operation of all alarm sensors on a system.
User can test the seismic detector.
User Rights – Service Engineer
User can create and edit other users on the system
with no restriction on user rights.
User can create and edit user profiles on the system.
User can configure calendars.
* Functions not enabled by default for this user but can be selected.
Access Control
1. Enter a Site Code, if required, for all cards assigned to this user profile. Refer
to the appendix section on Card Readers and Formats [âž™ 354].
2. Select the Access rights of this user profile for the doors configured on the
system. Options are:
- No access
- No time limit (i.e. 24 hour access)
- Calendar (if configured)
Users
A list of users assigned to this profile is displayed. Click on a user to view or edit
the user’s details.
You can create a new user profile based on an existing profile by clicking
Replicate. A new User Profile page is displayed.