Engineer programming via the browser
Configuring Communications
298
Vanderbilt
Installation & Configuration Manual
A6V10276959
01.05.2016
Commands Enable
Check this box to allow commands to be accepted from the
receiver.
Change User PINs
Check this box to allow user PINs to be changed from a remote
location. This feature is applicable only if commands are enabled
from the receiver.
Encryption Enable
Check this box to enable encryption on data to and from the
receiver.
Encryption Key
Enter a hexadecimal key (max. 32 digits) that will be used to encrypt
the data.
Note: The same key will need to be used at the receiver.
Virtual Keypad
Enables access to the panel with a virtual keypad i.e. a PC software
module that looks and behaves like an SPC keypad. It is available
with the SPC Com client.
Live
Streaming/Streaming
Mode
Specifies when live streaming of audio and video is available.
Options are Never, Always or Only after an alarm event. Default is
‘Only after an alarm event’.
Note: This setting has obvious privacy implications and therefore
should be enabled only where appropriate and subject to local laws
and regulations.
Network (Applies to the Ethernet connection only)
Network Enable
Check this box to allow events to be reported through the network.
Network Protocol
Select the type of network protocol for the receiver. Options are
UDP and TCP. TCP is recommended if supported by the receiver.
Receiver ID Address
Enter the IP address of the receiver.
Receiver IP Port
Enter the IP port that the EDP receiver is listening on.
Always Connected
If enabled the panel will keep a permanent connection to the
receiver. If disabled, the panel will only connect to the receiver after
an alarm event.
Panel Master
If enabled the panel is master of polling messages. Only applicable
to UDP connections.
Polling Interval
Enter the number of seconds between polls.
Polling Trigger
Enter the number of missing polls before a network connection fail
is registered. Only applicable to UDP connections.
Generate a Network
Fault
If polling fails, a network fault alert is generated.
Dial-up (Applies to the GPRS modem connection only)
Dial-up Enable
Check this box to report events through a dial-up connection.
Call type
Select type of call to use when dial up is enabled. Select GPRS.
GPRS protocol
Select the transport layer protocol used over the GPRS connection.
Options are UDP or TCP. Only applicable if Call Type is GPRS.
GPRS address
Enter the IP address of EDP receiver for GPRS connections. Only
applicable if Call Type is GPRS.
GPRS port
Enter the port that the EDP receiver is listening on for GPRS
connections Options are UDP or TCP. Only applicable if Call Type
is GPRS. Default is 50000.
GPRS Hangup
Timeout
Enter the time in seconds after which the GPRS call will hang up. (0
= stay connected until IP connection is up)
GPRS Autoconnect
Check this box to automatically trigger a GPRS call to the server if
an IP network fault occurs.
Dial-up on Net Fault
Check this box to report network faults on a dial-up test call.
Dial-up Interval 1*
Enter the number of minutes between dial-up test calls when
network link is up.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vanderbilt SPC53 Series and is the answer not in the manual?

Vanderbilt SPC53 Series Specifications

General IconGeneral
BrandVanderbilt
ModelSPC53 Series
CategoryPower Supply
LanguageEnglish

Related product manuals