TLS-450 Setup and Operation Screens Manual
127
• Minute: 0 to 59
• Meridiem: AM, PM (if 12 hour format)
Default: 02:00 (02:00 AM if 12 hour format)
Week Close Day
Allowable selections: Sunday to Saturday
Default: Sunday
Alarm Threshold Delivery Type
Alarm Threshold Delivery Type field is disabled (grayed out) when Ticketed Delivery is disabled. When
Ticketed Delivery is enabled, the selections for this field are Standard or Ticketed. If Alarm Threshold
Delivery type is set to Standard, the variance calculated by Periodic Reconciliation Report will be used. If
set to Ticketed, the variance calculated by Book Variance Report will be used to trigger the Product
Threshold Alarm.
Allowable selections: Standard, Ticketed
Default: Standard
Temperature Compensation
This field allows you to choose whether or not to calculate Business Inventory Reconciliation (BIR)
volumes using the Programmable Temperature Compensation (TC) value. Select STANDARD (the
default) if the meters are not temperature compensated. Select TC VOLUME if the meters are
temperature compensated (the calculation of all BIR volumes will be based on the TC value).
Allowable selections: Standard or TC Volume
Default: Disabled
Meter Calibration Offset%
The Meter Calibration offset applies to all of the site's dispenser meters and is applied to the dispensed
amount received. The default value is 0.000%.
Allowable selections: -1.000 to +1.000
Default: +0.000
BIR Status Warning Enable
Allowable selections: Enabled, Disabled
Default: Disabled
BIR Shift Close Warning Enable
Allowable selections: Enabled, Disabled
Default: Disabled
BIR Daily Close Warning Enable
Allowable selections: Enabled, Disabled
Default: Disabled