TLS-450 Setup and Operation Screens Manual
150
RS-232 End of Message
When this field is disabled, the 2 following fields (ETX Characters - Display and ETX Characters -
Computer) will be disabled. When this field is set to 'Enabled', both fields will become enabled and the
keypad will be accessible. You will be allowed to enter 1 or 2 ASCII characters for both the RS-232
Display and Computer Formats.
Allowable selections: Disabled, Enabled
Default: Disabled
ETX Characters - Display
Accepts non-printable characters through the GUI. Enter hex value as string with an opening and closing
bracket. Convert text string to char value and save or show. Example: Enter [0x06][0x15]
Allowable selections: 1 or 2 alpha-numeric characters (ASCII value 0 to 255)
Default: Blank
ETX Characters - Computer
Accepts non-printable characters through the GUI. Enter hex value as string with an opening and closing
bracket. Convert text string to char value and save or show. Example: Enter [0x06][0x15]
Allowable selections: 1 or 2 alpha-numeric characters (ASCII value 0 to 255)
Default: Blank
CDIM Advanced Tab Setups (page 1)
Comm Port Security
This entry does not apply to CDIMs.
Allowable selections: Enabled, Disabled
Default: Disabled
Security Code
This selection is only for DIMs that support pass-through - See Table 1 in Comm Setup - General
topic.
When the DIM is used in pass-through mode it does not pass DIM data. This field will be grayed out for
DIMs that do not support pass-through.
A case-sensitive code (Alpha and Enhanced Numeric (also punctuation characters), no spaces allowed
and no control characters. Each character will be represented by an asterisk in the field.
Allowable selections: A six-character alpha-numeric string
Default: Blank
RS-232 End of Message
When this field is disabled, the 2 following fields (ETX Characters - Display and ETX Characters -
Computer) will be disabled. When this field is set to 'Enabled', both fields will become enabled and the
keypad will be accessible. You will be allowed to enter 1 or 2 ASCII characters for both the RS-232
Display and Computer Formats.
Allowable selections: Disabled, Enabled
Default: Disabled