TLS-450 Setup and Operation Screens Manual
237
4 = Test rejected - excessive temperature change during test
6 = Test rejected -leak rate outlier
Leak Rate
Value range: -26.417 to 26.417 gal/hour (-99.999 to 99.999 L/hour)
Avg Temp
Value range: -40.0 to 140.0°F (-40.0 to 60.0°C)
Top Temp
Value range: -40.0 to 140.0°F (-40.0 to 60.0°C)
Brd Temp
Value range: -40.0 to 140.0°F (-40.0 to 60.0°C)
Temp Rate
Note: The Temp rate field does not use the offset factor 32 for conversion of °C to °F
Value range: -40.0 to 99.9°F/hour (-22.2 to 55.5°C/hour)
Disp Factor
Value range: 0 to 264,172 gal (0 to 999,999L)
Volume
Value range: 0 to 264,172gal (0 to 999,999L)
Test Interval
Value range: 0 to 672.0 hours (28 days maximum)
Last Dlvy
Value range: 0 to 9999.9 hours
Ullage
Value range: 0 to 264,172gal (0 to 999,999L)
Evap Rate
Value range: 0 to 2.6 gal/Hour (0 to 9.9L/Hour)
Control Buttons (right of screen)
CSLD Test Setup
Touch this button open the Tank Setup - CSLD Test Setup screen