TLS-450 Setup and Operation Screens Manual
272
Tank/Blend
Possible messages: Tank Label, Blend Label, Unmapped, Probeless or R (retired)
User FP
Fuel position as labeled by the station operator.
Locked
Possible messages: Yes or No. If yes, user has locked tank to meter mapping for this meter. Auto meter
mapping will not change it.
Control Buttons (Right side of screen)
Edit
This button is grayed out unless at least one record in the data view area is selected. When the desired
record is highlighted, touch the Edit button to display the 'Edit Tank Map' - dialog box which is described
below.
Edit Tank Map - Dialog Box
The selected record will populate the appropriate fields in the 'Edit Tank Map' dialog. When the 'Tank
Map' record has been edited using the 'Edit Tank Map' dialog, the new data will replace the old data in the
selected record. The fields of the Edit Tank Map dialog are described below:
• Locked - The user can only lock an entry if it is mapped or probeless. Retired entries are
unmapped, and cannot be locked. A Probeless tank assignment will be locked. You cannot
unlock the meter assignment (the Locked field is inactive). Touch the Down arrow to select: Yes
or No
• Tank/Blend - Touch the Down arrow to select: Tank Label, Blend Label, Unmapped, Probeless
or R (retired)
• User FP - Fuel position as labeled by the station operator. Allowable selections: 1 to 72
• Real FP - This field is read only - Fueling position reported by the POS terminal.
• Real Meter - This field is read only - Meter number reported by the POS terminal.
Max Meas. Volume
Touching this button displays the 'Enter Maximum Measured Volume' - dialog described below:
Volume - Touch the numeric keypad to the right of the Volume field and enter a desired maximum
measuring volume. This volume is the maximum allowed into the Manual Mapping screen. The normally
higher dispenses associated with commercial transactions are filtered out while you are manually
mapping meters. Allowable selections: 0 - 2.58 gal (0 to 10 litres).
Touch the button to accept edited value or button to abort the change and close the 'Enter
Maximum Measured Volume’ dialog box.
Clear All
When at least one event record is visible in the data view area this button is active. Touch the Clear All
button to remove all event records from the data view area.
More
Touching the 'More' button will shift the report over (right or left) to reveal additional columns outside of
the data view area.