TLS-450 Setup and Operation Screens Manual
143
Default: Unknown
Table 1. EDIMs Quick Reference Chart
DIM P/N
Software
Rev.
Protocol
Baud
Rate
(Default)
Parity
(Default)
Data Bits
(Default)
Stop Bits
(Default)
Notes
330280-
401
349643
GilbarcoEDIM
(Gilbarco GSite)
1200
Even
7
1
1
330280-
001
330273
VRProtocolDIM
(BIR)
9600
Odd
7
1
1, 2
NOTES:
1. DIMs implemented for V402.
2. Metric is the default setting for unit conversion. Requires 'G' in parameter string for gallon
units.
EDIM References
EDIM Parameter String Chart
Baud
Parity
Stop Bits
Data Bits
Conversion
String
Rate
String
Type
String
Bits
String
Bits
String
Units
B9
9600
N
None
H
1
V
7
G
Gallons
B4
4800
E
Even
S
2
D
8
M
Metric
B2
2400
O
Odd
-----
-----
-----
-----
I
Imperial
B1
1200
-----
-----
-----
-----
-----
-----
-----
-----
B6
600
-----
-----
-----
-----
-----
-----
-----
-----
B3
300
-----
-----
-----
-----
-----
-----
-----
-----
BG
-----
-----
-----
-----
-----
-----
-----
-----
-----
EDIM Card - Female D Connector Pin Outs
Pin Function
2 Transmit Data
3 Receive Data
7 Signal Ground

Table of Contents