WAGO-I/O-SYSTEM 750 CoDeSys 2.3 Runtime Environment 101
758-874/000-131 WAGO-I/O-IPC-C6
Manual
Version 1.0.0
Remanent memory area of 8 kB
Memory: 16#2000 (8 kB)
Retain: 16#FDF00 (1015 kB)
Sum: 16#FFF00 (1023 kB))
Remanent memory area of 16 kB
Memory: 16#4000 (16 kB)
Retain: 16#FBF00 (1007 kB)
Sum: 16#FFF00 (1023 kB)
Remanent memory area of 24 kB
Memory: 16#6000 (24 kB)
Retain: 16#F9F00 (999 kB)
Sum: 16#FFF00 (1023 kB)
Figure 35: Adaptation of the remanent memory area