260 Appendix WAGO-I/O-SYSTEM 750
758-874/000-131 WAGO-I/O-IPC-C6
Manual
Version 1.0.0
Table 134: Description of the configuration scripts for "NTP"
Parameter Status Call Output/Input Validity
NTP
Configuration Data
read
get_ntp_config
state
Entries for <value> are:
enabled
disabled
State
write
config_sntp
state=<value>
Entries for <value> are:
enabled
disabled
read
get_ntp_config
port
Port number of the NTP
server
Port
write
config_sntp
port=<value>
Specify the port number for
<value>.
read
get_ntp_config
time-server
Query the IP address of the
Time server.
Time Server
write
config_sntp
time-server=<value>
Enter the IP address of the
Time server. The <value>
can contain an IP address in
the format
number.number.number.
number or a domain name
as a string.
read
get_ntp_config
update-time
Query of the polling cycle
of the Time server.
Update Time
(seconds)
write
config_sntp
update-time=<value>
Specify the time-server's
query cycle (in s) for
<value>.
immediate