WAGO-I/O-SYSTEM 750 Appendix 291
758-874/000-131 WAGO-I/O-IPC-C6
Manual
Version 1.0.0
19.3.2 DPM_REDUNDANCY
This module supports the vice versa mechanism of the PROFIBUS redundancy
function.
Category
PROFIBUS function blocks
Name
DPM_REDUNDANCY
Type
Function block
Name of library
WAGO_DPM_01.lib
Required libraries
Applicable to
758-87x-111
Input parameter
Name Data Type Description
REBOOT BOOL IPC Reboot
ENABLE BOOL Function start
Output parameters
Name Data Type Description
RESET_MASTER BOOL Enable reboot of the PROFIBUS redundancy
partner
MASTER_
MODE
MODE_
INDICATION
See section Data Type
"MODE_INDICATION"
Variable declaration
Graphical illustration
Time referenced behavior
go active
>100ms
REBOOT
ENABLE
RESET_MASTER
MASTER_MODE
>100ms
go passive