4.8 Auto-Tuning
194 YASKAWA SIEPC71061705H GA700 Series Technical Manual
When the motor can rotate during Auto-Tuning, check for safety issues near the drive, motor, and machine.
Note:
If there are gears between the machine and motor shaft, Inertia Tuning or ASR Tuning are possibly not applicable.
Precautions before Using Deceleration Rate Tuning and KEB Tuning
Before Deceleration Rate Tuning or KEB Tuning, check these items:
Note:
Do not do Deceleration Rate Tuning if you use a braking resistor unit or a regenerative converter.
Do Deceleration Rate Tuning and KEB Tuning with the load attached to the motor.
Do not do Deceleration Rate Tuning or KEB Tuning for these applications:
In Deceleration Rate Tuning and KEB Tuning, the drive will automatically rotate the motor forward and accelerate and decelerate the
motor again and again.
On a machine that does not let the motor rotate forward
In applications with a small range of operation (trolleys and other such applications that can only move linearly)
In elevator applications
Applications where sudden acceleration and sudden deceleration are not applicable.
To do KEB Tuning with the external main circuit capacitors connected to the drive, set L3-26 [Additional DC Bus Capacitors] then do
KEB Tuning.
Do not do KEB Tuning or Deceleration Rate Tuning if the drive is set to use H1-xx = 16 [MFDI Function Select = Motor 2 Selection].
Failure to obey can cause an ov [Overvoltage] fault.