7.4 Fault
324 YASKAWA SIEPC71061705H GA700 Series Technical Manual
Code Name Causes Possible Solutions
CPF20 Control Circuit Error
A drive hardware problem occurred. Re-energize the drive.
If the fault stays, replace the control board or the drive. For
information about replacing the control board, contact
Yaskawa or your nearest sales representative.
Note:
Do a Fault Reset to clear the fault.
Fault trace is not available for these faults.
Code Name Causes Possible Solutions
CPF21 Control Circuit Error
A drive hardware problem occurred. Re-energize the drive.
If the fault stays, replace the control board or the drive. For
information about replacing the control board, contact
Yaskawa or your nearest sales representative.
Note:
Do a Fault Reset to clear the fault.
Fault trace is not available for these faults.
Code Name Causes Possible Solutions
CPF22 Control Circuit Error
A drive hardware problem occurred. Re-energize the drive.
If the fault stays, replace the control board or the drive. For
information about replacing the control board, contact
Yaskawa or your nearest sales representative.
Note:
Do a Fault Reset to clear the fault.
Fault trace is not available for these faults.
Code Name Causes Possible Solutions
CPF23 Control Circuit Error
A drive hardware problem occurred. Re-energize the drive.
If the fault stays, replace the control board or the drive. For
information about replacing the control board, contact
Yaskawa or your nearest sales representative.
Note:
Do a Fault Reset to clear the fault.
Fault trace is not available for these faults.
Code Name Causes Possible Solutions
CPF24
Control Circuit Error (Drive Unit
Signal Fault)
A drive hardware problem occurred. Re-energize the drive.
If the fault stays, replace the control board or the drive. For
information about replacing the control board, contact
Yaskawa or your nearest sales representative.
Note:
Do a Fault Reset to clear the fault.
Fault trace is not available for these faults.
Code Name Causes Possible Solutions
CPF26 Control Circuit Error
A drive hardware problem occurred. Re-energize the drive.
If the fault stays, replace the control board or the drive. For
information about replacing the control board, contact
Yaskawa or your nearest sales representative.
Note:
Do a Fault Reset to clear the fault.
Fault trace is not available for these faults.
Code Name Causes Possible Solutions
CPF27 Control Circuit Error
A drive hardware problem occurred. Re-energize the drive.
If the fault stays, replace the control board or the drive. For
information about replacing the control board, contact
Yaskawa or your nearest sales representative.
Note:
Do a Fault Reset to clear the fault.
Fault trace is not available for these faults.
Code Name Causes Possible Solutions
CPF28 Control Circuit Error
A drive hardware problem occurred. Re-energize the drive.
If the fault stays, replace the control board or the drive. For
information about replacing the control board, contact
Yaskawa or your nearest sales representative.
Note:
Do a Fault Reset to clear the fault.
Fault trace is not available for these faults.
Code Name Causes Possible Solutions
CPF29 Control Circuit Error
A drive hardware problem occurred. Re-energize the drive.
If the fault stays, replace the control board or the drive. For
information about replacing the control board, contact
Yaskawa or your nearest sales representative.
Note:
Do a Fault Reset to clear the fault.
Fault trace is not available for these faults.