12.6 E: Motor Parameters
742 YASKAWA SIEPC71061705H GA700 Series Technical Manual
HD: 2004 - 2021, 4002 - 4012
ND: 2004 - 2018, 4002 - 4009
HD: 2030 - 2211, 4018 - 4103
ND: 2021 - 2169, 4012 - 4089
HD: 2257 - 2415, 4140 - 4675
ND: 2211 - 2415, 4103 - 4675
4 : VT, 50Hz, 65% Vmid reduction
Use this derated torque pattern for torque loads proportional to three times the rotation speed. For example, fans
and pumps.
Note:
The voltage values in the figures are for 200 V class drives. Multiply the values by 2 for 400 V class drives.
HD: 2004 - 2021, 4002 - 4012
ND: 2004 - 2018, 4002 - 4009
HD: 2030 - 2211, 4018 - 4103
ND: 2021 - 2169, 4012 - 4089
HD: 2257 - 2415, 4140 - 4675
ND: 2211 - 2415, 4103 - 4675
5 : VT, 50Hz, 50% Vmid reduction
Use this derated torque pattern for torque loads proportional to two times the rotation speed. For example, fans
and pumps.
Note:
The voltage values in the figures are for 200 V class drives. Multiply the values by 2 for 400 V class drives.
HD: 2004 - 2021, 4002 - 4012
ND: 2004 - 2018, 4002 - 4009
HD: 2030 - 2211, 4018 - 4103
ND: 2021 - 2169, 4012 - 4089
HD: 2257 - 2415, 4140 - 4675
ND: 2211 - 2415, 4103 - 4675
6 : VT, 60Hz, 65% Vmid reduction
Use this derated torque pattern for torque loads proportional to three times the rotation speed. For example, fans
and pumps.
Note:
The voltage values in the figures are for 200 V class drives. Multiply the values by 2 for 400 V class drives.
HD: 2004 - 2021, 4002 - 4012
ND: 2004 - 2018, 4002 - 4009
HD: 2030 - 2211, 4018 - 4103
ND: 2021 - 2169, 4012 - 4089
HD: 2257 - 2415, 4140 - 4675
ND: 2211 - 2415, 4103 - 4675
7 : VT, 60Hz, 50% Vmid reduction