Parameter Details
12
12.8 H: Terminal Functions
YASKAWA SIEPC71061705H GA700 Series Technical Manual 853
Figure 12.109 DC Injection Braking Current through Analog Input
7: Torque Detection Level
Setting Value Function Description
7 Torque Detection Level
Enters a signal to adjust the overtorque/undertorque detection level.
When A1-02 = 0, 1, 5 [Control Method Selection = V/f, CL-V/f, OLV/PM], the drive rated current is 100%. When
A1-02 = 2, 3, 4, 6, 7, 8 [OLV, CLV, AOLV, AOLV/PM, CLV/PM, EZOLV], the motor rated torque is 100%.
Note:
Use this function with L6-01 [Torque Detection Selection 1]. This parameter functions as an alternative to L6-02 [Torque Detection
Level 1].
8: Stall Prevent Level During Run
Setting Value Function Description
8 Stall Prevent Level During
Run
Enters a signal to adjust the stall prevention level during run if the drive rated current is 100%.
Note:
The Stall Prevent Level During Run is based on the smaller of these two values:
Analog input value of MFAI terminal
L3-06 [Stall Prevent Level during Run]
Figure 12.110 Stall Prevention Level during Run with Analog Input
9: Output Frequency Lower Limit
Setting Value Function Description
9 Output Frequency Lower
Limit
Enters a signal to adjust the output frequency lower limit level as a percentage of the maximum output frequency.
B: PID Feedback
Setting Value Function Description
B PID Feedback
Enter the PID feedback value as a percentage of the maximum output frequency.
When you use this function, set b5-01 = 1 to 8 [PID Mode Setting = Enabled].
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV

Table of Contents

Related product manuals