EasyManua.ls Logo

YASKAWA GA700 Series

YASKAWA GA700 Series
1021 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter Details
12
12.10 n: Special Adjustment
YASKAWA SIEPC71061705H GA700 Series Technical Manual 927
Note:
Increase the setting value to increase the stability when the drive is operating at low speed. It can make the speed control less accurate.
When the motor rotates faster than the frequency reference at low speed, decrease the setting value in 0.1 Hz
increments.
Note:
If you set the value too low, the motor can rotate in reverse.
n4-71: Flux Estimation Method
No.
(Hex.)
Name Description
Default
(Range)
n4-71
(1B8B)
Expert
Flux Estimation Method
Sets the flux estimation method. Usually it is not necessary to change this setting.
0
(0, 1)
0 : Method 1
1 : Method 2
n4-72: Speed Feedback Mode
No.
(Hex.)
Name Description
Default
(Range)
n4-72
(1B8C)
Speed Feedback Mode
Sets the requirement for an encoder option when A1-02 = 4 [Control Method Selection =
Advanced Open Loop Vector].
0
(0, 1)
You can connect a PG-B3 or PG-X3 encoder option in AOLV control. You can use the encoder option for better
speed control precision.
Note:
When you use an encoder option in AOLV control to operate machinery, specialized tuning of the drive can be necessary. You should
usually set A1-02 = 3 [Control Method Selection = Closed Loop Vector] when you use an encoder option.
When you set this parameter to 1, also set the number of PG pulses in F1-01 [Encoder 1 Pulse Count (PPR)].
0 : Without Encoder
1 : With Encoder
n4-73: PGo Recovery Selection
No.
(Hex.)
Name Description
Default
(Range)
n4-73
(1B8D)
PGo Recovery Selection
Sets the restart mode to Without Encoder Mode or the With Encoder Mode when an encoder is
disconnected.
0
(0, 1)
Set A1-02 = 4 [Control Method Selection = AOLV] and n4-72 = 1 [Speed Feedback Mode = With Encoder] to
use this parameter.
Parameter F1-02 [Encoder Signal Loss Detect Sel] sets the drive response when the drive detects a disconnected
encoder. This parameter sets the drive to start up in the Without Encoder Mode or With Encoder Mode if the drive
detects PGo [Encoder (PG) Feedback Loss].
Note:
A PG-B3 encoder option is necessary to use this parameter. When you use a PG-X3 option, it is not necessary to set this parameter.
If the drive detects PGo, de-energize the drive and examine the wiring for the encoder.
0 : Without Encoder
1 : With Encoder
n4-74: Limit of Flux Loop
No.
(Hex.)
Name Description
Default
(Range)
n4-74
(1B8E)
Limit of Flux Loop
Sets the control level for flux loop control output.
250%
(100 - 500%)
If the torque is not sufficient because of 100% or more loads, increase the setting value in 20% increments. If the
setting is too high, overexcitation could occur and overheat the motor.
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV

Table of Contents