Parameter Details
12
12.10 n: Special Adjustment
YASKAWA SIEPC71061705H GA700 Series Technical Manual 929
■ n5-01: Feed Forward Control Selection
No.
(Hex.)
Name Description
Default
(Range)
n5-01
(05B0)
Feed Forward Control
Selection
Sets the feed forward function.
0
(0, 1)
0 : Disabled
1 : Enabled
■ n5-02: Motor Inertia Acceleration Time
No.
(Hex.)
Name Description
Default
(Range)
n5-02
(05B1)
Motor Inertia Acceleration
Time
Sets the length of time for the motor to accelerate from the stopped to the maximum frequency
with a single motor at the rated torque. Inertia Tuning automatically sets the motor acceleration
time.
Determined by C6-01, E5-
01, and o2-04
(0.001 - 10.000 s)
If you cannot do Inertia Tuning, calculate the motor acceleration time as shown here or measure the motor
acceleration time and set n5-02 to this value.
Calculate the Motor Acceleration Time
Use this formula to find the motor acceleration time:
• J
Motor
= Moment of inertia of motor (kg m
2
)
• n
rated
= Motor rated speed (min
-1
, r/min)
• T
rated
= Motor rated torque (N m)
You can also use this formula to find the motor acceleration time:
• f
rated
= Motor rated frequency (Hz)
• P = Number of motor poles
Calculate the Motor Acceleration Time
Use this procedure to calculate the motor acceleration time:
1. Use A1-02 [Control Method Selection] to set the control method.
2. Disconnect the motor and load.
3. Run Auto-Tuning to set motor parameters.
When you cannot do Auto-Tuning, manually set motor parameters with the information on the motor
nameplate or test reports. Set the E2 parameters for induction motors. Set the E5 parameters for PM motors.
4. Set C5 parameters [Automatic Speed Regulator (ASR)].
5. Set C1-01 [Acceleration Time 1] = 0.
6. Set L7-01 [Forward Torque Limit] to 100%.
7. Set the frequency reference to the same value as the motor rated speed.
8. Measure the length of time for the motor to reach the rated speed.
Show U1-05 [Motor Speed] on the keypad and enter the Run command (forward run).
9. Stop the motor.
10. Set n5-02 to the measured motor acceleration time value.
Reset all of the parameters that you changed to the previous setting values.
■ n5-03: Feed Forward Control Gain
No.
(Hex.)
Name Description
Default
(Range)
n5-03
(05B2)
Feed Forward Control Gain
Sets the ratio between load inertia and motor inertia. Inertia Tuning automatically sets the
Feedforward Control Gain value.
1.00
(0.00 - 100.00)
When you cannot do Inertia Tuning, use this procedure to set n5-03: