Parameter Details
12
12.10 n: Special Adjustment
YASKAWA SIEPC71061705H GA700 Series Technical Manual 939
n8-75: Medium Load Iq Level (low)
No.
(Hex.)
Name Description
Default
(Range)
n8-75
(05C4)
Expert
Medium Load Iq Level
(low)
Set n8-78 [Medium Load Id Current] to the percentage of load current (q-axis current) that you
will apply, where E5-03 [PM Motor Rated Current (FLA)] = a setting value of 100%.
50%
(0 - 255%)
Note:
If n8-74 [Light Load Iq Level] > n8-75, the drive will detect oPE08 [Parameter Selection Error].
The change is linear between n8-74 and n8-75 and the level of the pull-in current from n8-48 to n8-78 [Medium Load Id Current].
n8-77: Heavy Load Iq Level
No.
(Hex.)
Name Description
Default
(Range)
n8-77
(05CE)
Expert
Heavy Load Iq Level
Set n8-49 [Heavy Load Id Current] to the percentage of load current (q-axis current) that you will
apply, where E5-03 [PM Motor Rated Current (FLA)] = a setting value of 100%.
90%
(0 - 255%)
Note:
The change is linear between n8-75 [Medium Load Iq Level (low)] and n8-77 and the level of the pull-in current from n8-78 [Medium
Load Id Current] to n8-49 [Heavy Load Id Current].
n8-78: Medium Load Id Current
No.
(Hex.)
Name Description
Default
(Range)
n8-78
(05F4)
Expert
Medium Load Id Current
Sets the level of the pull-in current for mid-range loads.
0%
(0 - 255%)
n8-79: Pull-in Current @ Deceleration
No.
(Hex.)
Name Description
Default
(Range)
n8-79
(05FE)
Pull-in Current @
Deceleration
Sets the pull-in current that can flow during deceleration as a percentage of the E5-03 [PM Motor
Rated Current (FLA)].
50%
(0 - 200%)
If overcurrent occurs during deceleration, slowly decrease the setting in 5% increments.
Note:
When n8-79 = 0, the drive will use the value set in n8-51 [Pull-in Current @ Acceleration].
n8-84: Polarity Detection Current
No.
(Hex.)
Name Description
Default
(Range)
n8-84
(02D3)
Expert
Polarity Detection Current
Sets the current that the drive uses to estimate the initial motor magnetic pole as a percentage
where E5-03 [PM Motor Rated Current (FLA)] = 100%.
100%
(0 - 150%)
Note:
The drive automatically calculates this value when High Frequency Injection Auto-Tuning completes successfully.
WARNING! Sudden Movement Hazard. Make sure that the polarity is correct before you send a Run command. If the drive
incorrectly detects the polarity, the drive can rotate in the direction opposite of the Run command and cause serious injury or
death.
When you use a Yaskawa motor, check the motor nameplate for an Si value and set this parameter "Si × 2".
Consult the motor manufacturer for information about maximum setting values.
Find the Polarity of Magnetic Poles
When you start operation, the drive estimates the magnetic poles and finds the polarity of the magnetic poles.
When A1-02 = 7 [Control Method Selection = CLV/PM], the drive finds the polarity of the magnetic poles only at
the first startup.
Use U6-57 [PolePolarityDeterVal] to make sure that the drive correctly estimated the polarity of the magnetic
poles.
When you do High Frequency Injection Auto-Tuning, the drive automatically sets n8-84.
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV

Table of Contents

Related product manuals