EasyManua.ls Logo

YASKAWA GA700 Series

YASKAWA GA700 Series
1021 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12.12 T: Auto-Tuning
970 YASKAWA SIEPC71061705H GA700 Series Technical Manual
T4-06: Motor Rated Voltage
No.
(Hex.)
Name Description
Default
(Range)
T4-06
(3135)
Motor Rated Voltage
Sets the rated voltage (V) of the motor.
200 V Class: 200.0 V,
400 V Class: 400.0 V
(200 V Class: 0.0 - 255.0 V,
400 V Class: 0.0 - 510.0 V)
T4-07: Motor Rated Current
No.
(Hex.)
Name Description
Default
(Range)
T4-07
(3136)
Motor Rated Current
Sets the rated current (A) of the motor.
Determined by o2-04, C6-
01
(10% to 200% of the drive
rated current)
Note:
The value set here becomes the base value for motor protection, the torque limit, and torque control.
T4-08: Motor Rated Capacity
No.
(Hex.)
Name Description
Default
(Range)
T4-08
(3137)
Motor Rated Capacity
Sets the motor rated power in the units set in o1-58 [Motor Power Unit Selection].
Determined by E9-10
(0.10 - 650.00 kW)
T4-09: Number of Poles
No.
(Hex.)
Name Description
Default
(Range)
T4-09
(3138)
Number of Poles
Sets the number of motor poles.
Determined by E9-01
(2 - 120)
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV

Table of Contents

Related product manuals