7-6 Logic Task ECODRIVE03-FL*-04VRS
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
Other Assignments:
No Command (can be used as a placeholder)
End of the assignment list
End of a term
Operands:
For the load assignments and the logical assignments, the bits of Groups
M0, M1, M4 - M6, M8, Q0 - Q3, I0 - I4 and C0 and C1 are allowed as
operands.
For the save, set and re-set assignments, the bits of Groups M5, M6, and
Q0 - Q3 are allowed as operands.
Target operands, which have already been assigned to a function by a
parameter, cannot be used. Otherwise, the error message "F- 02 21
Logic Task Program Error" is issued.
Likewise, no output bit in the NC Program may be written if it has already
been used as a target operand in the logic task.
Constants:
Source bits C0.00.0 to C0.01.7
All bits have a defined status of FALSE.
Source bits C1.00.0 to C1.01.7
All bits have a defined status of TRUE.
NOP
END
)
Source Operand
Target Operand
Constant 0
Constant 1