10-10 Interface ECODRIVE03-FL*-04VRS
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
Marker Flags
The marker flags can be distinguished as follows:
Source Bytes Function
0 00...05 System Marker Flags (Inputs)
1 00...03 System Marker Flags (Outputs)
2 00...19 NC Marker Flags
3 00...07 Saved NC Marker Flags
4 00...09 NC Transfer Marker Flags Å Logic Task
4 10...13 NC Transfer Marker Flags Å Logic Task
cleared after processing of the Logic Task
5 00...09 Logic Task Transfer Marker Flags Å NC
6 00...18 Saved Logic Task Marker Flags
6 19 System Byte (Parameter B010 = 4) saved
6 20...36 Logic Task Marker Flags
6 37...39 Logic Task Marker Flags for Command TXT 3 and Serial
Interface Status 25
8 00...19 Command Marker Flags via Serial Interface
Fig. 10-6: Marker Flag Categories
Here, the requirements are mirrored.
These marker flags are read-only using the Logic Task and the NC Task.
M0.00
Bit Function Source
0 Parameter Input or Fieldbus
1 Manual/Automatic Input or Fieldbus
2 Start Input or Fieldbus
3 Stop Input or Fieldbus
4 Jog forward Input or Fieldbus
5 Jog reverse Input or Fieldbus
6 Clear errors Input or Fieldbus
7 Drive Enable Input or Fieldbus
Fig. 10-7: Marker Flag System Inputs
System Marker Flags (Inputs)