9-26 Parameters ECODRIVE03-FL*-04VRS
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
AA13 Press: Signal, Intermittent
M2.02.2 M2.02.3
Output Bit: Press (Intermittent)
M2, M3, M4
EMD : Q3.00.0-Q3.03.7
DKC21.3 : Q0.00.4-Q0.01.3
DKC 3.3 : Q2.02.0-Q2.05.7
Input Bit :
Press, Intermittent/Continuous (0/1)
00.00.0 = Function Off
M0 – M5 ; M8 ; I0 – I4 ; Q0 – Q3
This function is only valid as an option when Parameter AA12 is
programmed. Here, a second output can be set when the press is run
intermittently. If this parameter is not activated, the output from Parameter
AA12 is used for the press in continuous operation or in intermittent
operation.
In addition to the output Press in Parameter AA12, a second press output
can be programmed.
Depending on the input/marker Press Intermittent/Continuous operation,
one of the two outputs is processed.
Input
Press
On/Off
Input
Intermittent/
Continuous
Output Press
(Intermittent
Operation AA13)
Output Press
(Continuous
Operation AA12)
Output Press AA12
Without Parameter
AA13
00 0 0 0
10 1 0 1
01 0 0 0
11 0 1 1
Fig. 9-11: Output Press Intermittent / Continuous