Bosch Rexroth OptiFeed-FS EcoDrive 03 FLP04VRS - C005 Position Feedback 2 Type; C006 Feedback 2 Resolution

Bosch Rexroth OptiFeed-FS EcoDrive 03 FLP04VRS
490 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9-46 Parameters ECODRIVE03-FL*-04VRS
DOK-ECODR3-FL*-04VRS**-FK01-EN-P
C005 Position Feedback 2 Type
00 0 0 0
Encoder Type
0 = rotary
1 = linear
Distance-Coded Measurement System:
0 = no distance-coded measurement system
1 = distance-coded reference marks
Direction:
0 = not inverted
1 = inverted
Absolute Measurement:
x0 = no absolute measurement possible
01 = absolute measurement possible and active
(Encoder is treated as absolute)
11 = Absolute measurement possible, but not active
This parameter is used to set the most important properties of the
interface encoder (position encoder 2).
Remark:
In absolute measuring systems with memory, absolute measurement is
automatically set to x1.
C006 Feedback 2 Resolution
00005000
Pulses/Revolution (rotary encoders)
00005000
mm / Graduation Mark (linear encoders)
Input is in 0.0000001 mm
See also Parameter C003.